China ENI-8-4080C aluminum profile is lightweight and corrosion-resistant and can be used to make medical instruments Products, EI

ENI-8-4080C aluminum profiles are lightweight and corrosion-resistant and can be used to make stretcher frames, medical equipment, medical beds, etc. in the medical industry.

Product Description

ENI-8-4080C aluminum profiles have become an ideal material for frame equipment in the medical field due to their core properties of being lightweight and corrosion-resistant, playing a key role in stretcher trolleys, medical equipment, and medical beds.

Stretcher Trolley Frame

As the core material of the stretcher trolley frame, its lightweight characteristics greatly reduce the carrying burden of medical staff, making it easier to shuttle flexibly in narrow ward corridors and elevators; the anodized surface treatment of ENI-8-4080C aluminum profiles gives it excellent corrosion resistance and can withstand frequent wiping with disinfectant water, and it can still maintain a stable structure after long-term use.

Medical Devices & Equipment

In the field of medical devices, it is often used to build monitor brackets, infusion pump racks, etc. The T-slot design supports the rapid installation of various accessories, making it easy to adjust the equipment layout according to clinical needs.

Medical Beds

In the application of medical beds, multiple ENI-8-4080C aluminum profiles are combined into a stable bed frame main body through special connectors, which can not only withstand the patient's weight pressure, but also realize bed lifting, folding and other functions through modular design. At the same time, its corrosion resistance is also suitable for the humid and bacterial environment of hospitals, reducing bacterial growth and adding guarantee to medical safety.

Lightweight
Reduces burden on medical staff & improves mobility
Corrosion-Resistant
Anodized surface withstands disinfectants & humidity
Modular
T-slot design for rapid, flexible accessory installation
Model Physical Drawing Data Map Unit Mass Moment Of Inertia Sectional Resistance Moment
E&I-6-4040 ENI-8-4040C ENI-8-4040C_00 1.25kg/m Ix:8.65cm4 Iy:8.65cm4 Wx:4.33cm3 Wy:4.33cm3
E&I-8-4040F 4040f E4040F 1.81kg/m Ix:11.23cm4 Iy:11.23cm4 Wx:5.62cm3 Wy:5.62cm3
E&I-8-4040GG 4040GG E4040GG 1.32kg/m Ix:7.73cm4 Iy:7.73cm4 Wx:3.87cm3 Wy:3.87cm3
E&I-8-4040T ENI-8-4040T ENI-8-4040T_00 0.89kg/m Ix:5.09cm4 Iy:5.09cm4 Wx:2.55cm3 Wy:2.55cm3
E&I-8-4040LC ENI-8-4040LC ENI-8-4040LC_00 1.13kg/m Ix:6.37cm4 Iy:6.37cm4 Wx:3.18cm3 Wy:3.18cm3
E&I-8-4040W ENI-8-4040W ENI-8-4040W_00 1.33kg/m Ix:7.82cm4 Iy:7.82cm4 Wx:3.91cm3 Wy:3.91cm3
E&I-8-4040B bnvcuj-300x300 ENI-8-4040B_00-300x300 1.64kg/m Ix:8.65cm4 Iy:8.65cm4 Wx:4.33cm3 Wy:4.33cm3
E&I-8-4040LD ENI-8-4040LD ENI-8-4040LD_00 1.05kg/m Ix:6.21cm4 Iy:6.21cm4 Wx:3.11cm3 Wy:3.11cm3
E&I-8-4040C ENI-8-4040LC ENI-8-4040LC_00 1.29kg/m Ix:7.32cm4 Iy:7.32cm4 Wx:3.66cm3 Wy:3.66cm3
E&I-8-4040D ENI-8-4040D ENI-8-4040D_00 1.85kg/m Ix:9.98cm4 Iy:9.98cm4 Wx:4.99cm3 Wy:4.99cm3
E&I-8-4040E ENI-8-4040E ENI-8-4040E_00 1.67kg/m Ix:8.96cm4 Iy:8.96cm4 Wx:4.48cm3 Wy:4.48cm3
E&I-8-4040EE ENI-8-4040EE ENI-8-4040EE_00 1.65kg/m Ix:8.63cm4 Iy:8.96cm4 Wx:4.32cm3 Wy:4.48cm3
E&I-10-4040H 4040h E4040H 1.51kg/m Ix:8.65cm4 Iy:8.65cm4 Wx:4.33cm3 Wy:4.33cm3
E&I-8-4040R ENI-8-4040R ENI-8-4040R_00 1.50kg/m Ix:7.10cm4 Iy:7.10cm4 Wx:3.55cm3 Wy:3.55cm3
E&I-10-4060H ENI-10-4060H ENI-10-4060H_00 2.27kg/m Ix:13.33cm4 Iy:27.69cm4 Wx:6.67cm3 Wy:9.23cm3
E&I-8-4080GA ENI-8-4080GA ENI-8-4080GA_00 2.31kg/m Ix:14.41cm4 Iy:54.58cm4 Wx:7.21cm3 Wy:13.65cm3
E&I-8-4080C 4080C E4080C 2.22kg/m Ix:13.72cm4 Iy:52.30cm4 Wx:6.86cm3 Wy:13.08cm3
E&I-8-4080M ENI-8-4080M ENI-8-4080M_00 2.28kg/m Ix:13.99cm4 Iy:52.91cm4 Wx:7.00cm3 Wy:13.23cm3
E&I-8-4080F 4080f E4080F 3.30kg/m Ix:19.66cm4 Iy:79.30cm4 Wx:9.83cm3 Wy:19.83cm3
E&I-10-4080H ENI-10-4080H ENI-10-4080H_00 2.64kg/m Ix:16.14cm4 Iy:61.71cm4 Wx:8.07cm3 Wy:15.43cm3
E&I-8-4080 ENI-8-4080 ENI-8-4080_00 2.94kg/m Ix:16.48cm4 Iy:65.91cm4 Wx:8.24cm3 Wy:16.48cm3
E&I-8-4080I ENI-8-4080I ENI-8-4080I_00 3.26kg/m Ix:19.11cm4 Iy:73.31cm4 Wx:9.56cm3 Wy:18.33cm3
E&I-8-40120 ENI-8-40120E ENI-8-40120_00 4.28kg/m Ix:25.52cm4 Iy:219.79cm4 Wx:12.76cm3 Wy:36.63cm3
E&I-8-40120E ENI-8-40120E ENI-8-40120E_00 4.65kg/m Ix:25.96cm4 Iy:238.31cm4 Wx:12.98cm3 Wy:39.71cm3
E&I-8-40160 ENI-8-40160 ENI-8-40160_00 6.23kg/m Ix:39.83cm4 Iy:559.92cm4 Wx:19.92cm3 Wy:69.99cm3
E&I-8-40160B ENI-8-40160B ENI-8-40160B_00 5.24kg/m Ix:31.92cm4 Iy:457.75cm4 Wx:15.96cm3 Wy:57.22cm3

Frequently Asked Questions

What makes ENI-8-4080C aluminum profiles suitable for stretcher trolleys?

Their lightweight properties significantly reduce the physical load on medical personnel when navigating tight corridors and elevators. Additionally, their corrosion-resistant anodized coating ensures they remain undamaged by routine disinfectant cleaning.

How does the T-slot design benefit medical equipment setups?

The T-slot design allows for the fast, flexible attachment and adjustment of modular medical hardware such as infusion pump stands and monitor mounts, facilitating rapid adjustment for clinical needs.

Can these profiles support heavy loads such as medical bed frames?

Yes, when assembled using specialized connectors, ENI-8-4080C profiles create highly stable bed frames that safely manage patient weight and allow complex functionalities like folding and lifting mechanisms.

Why is corrosion resistance crucial in a hospital setting?

Hospitals employ harsh chemical disinfectants and maintain specific humidity levels. The anodized finish of the profiles prevents degradation, helps limit bacterial accumulation, and ensures compliance with strict medical hygiene standards.

Are these profiles easy to integrate with custom medical equipment?

Yes, the modular engineering structure enables seamless integration with a wide variety of medical setups, allowing technicians to modify or expand configurations with minimal disruption.

Related Products